Water Infrastructure

The Water Department does a large variety of system maintenance on Herriman's wells, pumps, and chemical injection systems. They also do annual maintenance on pressure relief valves and air vacs. Crews annually exercise all valves in the water system and flush every fire hydrant and dead end.

Statistics

Herriman continues to grow rapidly, keeping the Water Department busy and productive.

Connection type Connections as of January 2020
Culinary 13,013
Secondary 3,901
  Total 16,914

InfrastructureCity maintains
Water lines197 miles
Fire hydrants2,114
Water main valves 6,512
Pump stations 8
Total pump station capacity 7,302 gallons per minute



Water Sources

  • Hamilton well
  • Well #1
  • Well #2
  • Well #3
  • Jordan Valley Water
  • Arnold Hollow Springs
  • Stillman well

Water gushes out of an opening in the road as a City employee watches the flushing process


Water Samples

Herriman City takes numerous water quality and chemical level samples throughout the system on a daily basis (all 365 days of the year) to guarantee water quality and safety. Due to absence or low levels present, many of the following source samples have been changed to a reduced monitoring schedule every three or six years. The Water Department also performs a full-spectrum test on all wells every other year to monitor for many contaminants not required for monitoring.

Several large pipes and valves


Distribution system samples Number of samples Additional information
Fluoride 4-5 biweekly = 9 per month One sample is sent to the state lab per month to ensure accuracy of our test equipment
Disinfection byproduct 4 per quarter = 16 per year Monitoring the effects of chlorine in the water.
Lead and copper 20 every 3 years Lead and copper samples must be taken in homes that have copper water lines with seed solder installed (between 1983 and 1988). This is done to determine if the water pH is leaching contaminants out of the pipes in the home.
Chlorine residuals 30 per month = 360 per year Presence of chlorine is an indicator that there will not be bacteria in the water.
Bacteriological 30 per month = 360 per year
Taken to ensure no bacteria is present in the water.


Source samplesNumber of samples
Inorganics and metals1 every 3 years x 4 sources = 4 every 3 years
Nitrates1 per year x 4 sources = 4 per year
Pesticides 2 every 3 years x 4 sources = 8 every 3 years
Radionuclides 1 every 6 years x 4 sources = 4 every 6 years
Sulfates, sodium, TDS (total dissolved solids) 1 every 3 years x 4 sources = 4 every 3 years



Annual Water Quality Report

Read the full water quality report from 2019 by clicking on the button below.

The cover of a water quality report brochure that shows a picture of a pond in Herriman



Contact Us

Hours

7:30 a.m. - 5:30 p.m. | Monday - Friday

Phone

801-446-5323

Email

water@herriman.org

Justun Edwards • Director of Public Works
Phone: 801-446-5323 | Email

Herriman City

Luke Sieverts • Water Manager
Phone: 801-446-5323 | Email

Herriman City